Flow measurement
Flow nozzle
Long-radius and ISA 1932 flow nozzles for steam and vapour lines from 50 mm to 630 mm, in AISI 316.
Flow measurement
Classical Venturi tubes in three construction types, 50 mm to 1200 mm, manufactured to ISO 5167 and BS 1042.
A Venturi tube has a conical convergent entry, a cylindrical throat and a conical divergent outlet. Because the divergent cone recovers pressure, the permanent pressure loss is substantially lower than an orifice plate — the reason Venturi meters are chosen where pumping energy matters.
Tubes are manufactured to ISO 5167 and BS 1042. The three types differ in how the internal surface of the entrance cone, and the profile at the intersection of cone and throat, are produced.
| Line size | Type A: 100–800 mm (4"–32" NB) · Type B: 50–250 mm (2"–10" NB) · Type C: 200–1200 mm (8"–48" NB) |
|---|---|
| Types | Type A: cast convergent section · Type B: machined convergent section · Type C: rough welded sheet-iron convergent section |
| Accuracy | Type A: ±0.7% · Type B: ±1.0% · Type C: ±1.5% |
| Flange material | ASTM A105, A182 Gr. F11, A182 Gr. F22, SS304, SS316 |
| Standards | ISO 5167, BS 1042 |
Contact
Send the enquiry with line size, pressure class and material grade.
Flow measurement
Long-radius and ISA 1932 flow nozzles for steam and vapour lines from 50 mm to 630 mm, in AISI 316.
Flow measurement
Orifice plate assemblies with studs, nuts, jack bolts and gaskets, for lines from 15 mm to 1500 mm (1/2"–60" NB).
Flow measurement
Aerofoil elements for air and gas flow in square or rectangular ducts from 500 mm and above, with low permanent pressure loss.
Contact
Tell us the product, material, size and quantity. We reply within one working day.